Excellent hmi touch screen manufacturer: Order principle: That is, in accordance with the order of processing events, access to view the order (such as from the whole to a single item, from large to small, from the top to the bottom, etc.) and control processes, such as the design of monitoring management and human-machine dialogue interface and its secondary interface. Functional principle: That is, according to the specific functional requirements of the object application environment and occasions, various subsystem control types, parallel processing requirements of the same interface of different management objects and simultaneous requirements of multiple dialogues, etc., the human-computer interaction interface is designed with multi-level menus, hierarchical prompt messages and multiple dialogues, so that users can easily distinguish and master the usage rules and characteristics of the interactive interface and improve its user friendliness and ease of operation. Find additional info at hmi touch screen.
Selecting the installation method: The installation mode of plc system is divided into centralized, remote i/o and distributed with multiple plc networking. Centralized hardware does not need to be set to drive remote i/o hardware, the system response is fast and cost is low; Remote I/O type is suitable for large systems, the system device distruibution range is very wide, remote i/o can be scattered installed near the field device, the connection is short, but need to add drivers and remote i/o power supply; The distrbuted network of multiple plc is suitable for the occasions where multiple devices are independently controlled and interconnected, and small plc can be selected, but communication module must be attaced.
Determine the task that should be performed by human and computer respectively to complete the system function: There are two ways of task analysis. One is to start from the actual, through the analysis of the original application system in a manual or semi-manual state, it will be mapped to a set of similar tasks performed on the human-computer interface; the other is to study the system requirements specifications to derive a set of user tasks coordinated with the user model and system assumptions. Techniques such as stepwise refinement and object-oriented analysis are also applicable to task analysis. Stepwise refinement techniques can continuously divide the task into subtasks until the requirements for each task are clear; and object-oriented analysis techniques can be used to identify all the objective objects associated with the application and the actions associated with the objects.
The Fourth Step: Communication Mode Preference is given to the HMI Panel itself with lower computer drive touch screen. Firstly, this is will be more convenient and simple in the definition of the subsequent project address and conversion, becuase if you choose Modbus compatible devices, it is necessary to convert the HMI touch screen monitoring address according to the rules of the definition of different lower computer(PLC) manufacturer, which not only greatly increase the workload of engineers and also easy to covert the wrong. Secondly, needing to draw up in advance, a communication program for the entire project. Do it need the ethernet to communicate with the upper computer, or need two rs485 to be maste or slave station communication, or through one rs485 and one rs232 communication to achieve.
In 2022, in order to meet the new needs of customers and the market, our MochuanDrives merged with a professional manufacturer of highly customized servo motors, with more than 20 years of experience in research and development, manufacturing and service of servo motors and brushless motors, especially good at tailor-made high-end motors with special specifications from scratch, until the stable manufacturing of large quantities. With NO MOQ, before large quantities needing to get 100% stable quality confirmation from our customers. Discover additional information on mochuan-drives.com.
Why touch panel interface always fail to communicate with PLC? Common reasons why touchscreens do not communicate with PLCs 1. whether the correct communication protocol is selected (Modbus, Profibus, CANopen, etherCAT) 2. Is the communication line normal (RS232 rxd TXD GND RS485 a+B-CANopen CAN_L CAN_H CAN_GND ether cat network cable) 3. Whether the communication parameters are correct (station number, baud rate, parity bits) 4. Whether there is interference The program determines that the communication between HMI operator interface and plc has fialed
Multiple color of shell and panel cutout for selecting, it is more flexible to match different project to improve the overall aesthetics and practical. Suggestions and recommendations to our customers through over a decade field experience industry and industry solution through software and hardware, if you work with us. If require the special technology, special function, special size, special parameter, special color, shape or special performance of ihm, welcome contact us for ODM. Mochuan hmi panel manufacturers will be very seriously and give timely feedback.
The plastic enconomic resistive HMI panel is very high advantage competitive series. There are multiple parameter, resolution, serial port to select for user to achieve real matching per project budget for one size. But it does not mean, this type HMI touch panel performance, resolution…etc is not in perfect but more flexible. For example, there are 800×480, 1024×600 resolution, ethernet, 2xRS485, 2xRS232, RS422 are in optional for 7inch touchscreen HMI.
Industrial grade fully enclosed embedded industrial hmi touch panel can perfectly cope with all kinds of harsh environment, but also can bring more convenient management services: Installation of embedded industrial hmi touch screen panel in the electrical room cabinet is more conducive to intelligent monitoring and management of the equipment in the electrical room. Through the touch screen monitoring display, you can monitor and detect the running temperature, power output, output power and other conditions of the electrical chassis cabinet in real time to ensure the stable and efficient operation of the electrical room.
Human-machine interface refers to the field of human and machine in information exchange and functional contact or mutual influence or interface said human-machine bonding surface, information exchange, functional contact or mutual influence, refers to the hard contact and soft touch of human and machine, this bonding surface includes not only the direct contact of the point line surface, but also the role of space for information transfer and control at a distance.